<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-13 13-07-24
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 4/5, 73 dBuV NOSTALGI
Pilot RDS Phase Difference
6.1 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
5 kHz 66 kHz 12269 0,0163
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,7 dBr 5,49 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Freeman - Aj "
AF EON
92.7, 94.3, 99.5, 100.5 MHz -
FM Scope Max at: 66 kHz MIN: 5 kHz % above 76 kHz: 0,0163 Acquired: 2024/08/13 13.06.20 Total samples: 12269 Equivalent time: 0:10:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,6 dBr MIN: 3,7 dBr AVE: 5,49 dBr % above 12,2 dBr: 0,0 Last value: 3,8 dBr (2024/08/13 13.06.20) 12.52 12.54 12.56 12.58 13.00 13.02 13.04 13.06 0 2 4 6 Pm [dBr]